{"title":"Fiber Patch Cables","description":"","products":[{"product_id":"mpo-8-to-mpo-8-single-mode-400g-fiber-patch-cable","title":"MPO-8 to MPO-8 Single-Mode 400G Fiber Patch Cable","description":"\u003cdiv class=\"b2b-product-copy\"\u003e\n\u003cp\u003e\u003cstrong\u003eB2B RFQ product.\u003c\/strong\u003e This item is supplied to project requirements and is not sold at a fixed online price.\u003c\/p\u003e\n\u003cp\u003eA low-loss single-mode MPO-8 patch cable for 400G optical links in AI computing centers, HPC clusters, and high-density data centers.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEight active G.657.A1 single-mode fibers\u003c\/li\u003e\n\u003cli\u003eMPO\/APC female connectors at both ends\u003c\/li\u003e\n\u003cli\u003eType B polarity with key-up to key-up orientation\u003c\/li\u003e\n\u003cli\u003eLow insertion loss for demanding 400G links\u003c\/li\u003e\n\u003cli\u003eCustom length, labeling, packaging, and test-report options\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eFiber type\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eG.657.A1 single-mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eActive fiber count\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eConnector A\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e12-fiber MPO\/APC female housing, 8 active fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eConnector B\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e12-fiber MPO\/APC female housing, 8 active fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003ePolarity\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eType B, key-up to key-up\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eCable\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e3.0 mm, yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eInsertion loss\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e\u0026lt;= 0.35 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eReturn loss\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e\u0026gt;= 65 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eTest wavelengths\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e1310 nm and 1550 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eReference reach\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eUp to 150 m in the referenced application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e400G single-mode switch-to-switch links\u003c\/li\u003e\n\u003cli\u003eAI and HPC cluster interconnects\u003c\/li\u003e\n\u003cli\u003eHigh-density data-center optical cabling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003ePlease specify required length, quantity, polarity, connector gender, jacket requirement, labeling, and destination country. OEM labeling, custom packaging, and project-specific test reports are available on request.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/fr\/pages\/contact\"\u003e\u003cstrong\u003eRequest a Quote\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"HyperNet","offers":[{"title":"Default Title","offer_id":51545072763113,"sku":"HN-MPO8-MPO8-SM-400G","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/6262\/3465\/files\/01-mpo8-mpo8-sm-400g-product_a02cf027-5a5c-4d9a-b0cd-cbec31781c70.png?v=1784527244"},{"product_id":"mpo-8-to-2x-mpo-8-single-mode-400g-to-2x200g-breakout-cable","title":"MPO-8 to 2x MPO-8 Single-Mode 400G to 2x200G Breakout Cable","description":"\u003cdiv class=\"b2b-product-copy\"\u003e\n\u003cp\u003e\u003cstrong\u003eB2B RFQ product.\u003c\/strong\u003e This item is supplied to project requirements and is not sold at a fixed online price.\u003c\/p\u003e\n\u003cp\u003eA single-mode breakout cable that converts one 400G MPO interface into two 200G branches for high-density AI and data-center interconnects.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEight active fibers on the input side\u003c\/li\u003e\n\u003cli\u003eTwo branches with four active fibers per branch\u003c\/li\u003e\n\u003cli\u003eMPO\/APC female connector housings on all ends\u003c\/li\u003e\n\u003cli\u003eG.657.A1 single-mode fiber with yellow LSZH construction\u003c\/li\u003e\n\u003cli\u003eCustom overall length and branch length available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eFunction\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e400G to 2 x 200G optical breakout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eFiber type\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eG.657.A1 single-mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eFiber mapping\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e8 active fibers to 2 x 4 active fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eInput connector\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e12-fiber MPO\/APC female housing, 8 active fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eOutput connectors\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e2 x 12-fiber MPO\/APC female housings, 4 active fibers per branch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eCable construction\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e3.0 mm input; 2 x 3.0 mm branch cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eJacket\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eYellow LSZH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eKey orientation\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eKey-up reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eFanout reference\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e0.2 m from input connector to junction in the source drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e400G switch port to two 200G endpoints\u003c\/li\u003e\n\u003cli\u003eAI and HPC leaf-spine fabrics\u003c\/li\u003e\n\u003cli\u003eSingle-mode data-center breakout cabling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering note:\u003c\/strong\u003e The source slide defines construction and fiber mapping but not IL\/RL values; those values are intentionally not claimed.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003ePlease specify overall length, branch length, quantity, fiber mapping, jacket rating, labels, and destination country. OEM labeling, custom packaging, and project-specific test reports are available on request.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/fr\/pages\/contact\"\u003e\u003cstrong\u003eRequest a Quote\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"HyperNet","offers":[{"title":"Default Title","offer_id":51545072795881,"sku":"HN-MPO8-2MPO8-SM-400G-2X200G","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/6262\/3465\/files\/02-mpo8-2x-mpo8-sm-400g-2x200g-product_4f31f4d8-a518-4a31-a5c7-c21f9024c2f5.png?v=1784527289"},{"product_id":"mpo-8-to-mpo-8-om4-multimode-400g-fiber-patch-cable","title":"MPO-8 to MPO-8 OM4 Multimode 400G Fiber Patch Cable","description":"\u003cdiv class=\"b2b-product-copy\"\u003e\n\u003cp\u003e\u003cstrong\u003eB2B RFQ product.\u003c\/strong\u003e This item is supplied to project requirements and is not sold at a fixed online price.\u003c\/p\u003e\n\u003cp\u003eAn OM4 multimode MPO-8 patch cable for short-reach 400G links in AI clusters, HPC systems, and high-density data centers.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEight active OM4 multimode fibers\u003c\/li\u003e\n\u003cli\u003eMPO\/APC female connectors at both ends\u003c\/li\u003e\n\u003cli\u003eType B polarity with key-up to key-up orientation\u003c\/li\u003e\n\u003cli\u003eLow insertion loss for high-speed multimode links\u003c\/li\u003e\n\u003cli\u003eMagenta 3.0 mm cable and custom length options\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eFiber type\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eOM4 multimode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eActive fiber count\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eConnector A\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e12-fiber MPO\/APC female housing, 8 active fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eConnector B\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e12-fiber MPO\/APC female housing, 8 active fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003ePolarity\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eType B, key-up to key-up\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eCable\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e3.0 mm, magenta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eInsertion loss\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e\u0026lt;= 0.25 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eReturn loss\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e\u0026gt;= 45 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eTest wavelengths\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e850 nm and 1300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eReference reach\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eUp to 50 m in the referenced application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e400G multimode switch-to-switch links\u003c\/li\u003e\n\u003cli\u003eAI and HPC cluster interconnects\u003c\/li\u003e\n\u003cli\u003eShort-reach data-center optical cabling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003ePlease specify required length, quantity, polarity, connector gender, jacket requirement, labels, and destination country. OEM labeling, custom packaging, and project-specific test reports are available on request.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/fr\/pages\/contact\"\u003e\u003cstrong\u003eRequest a Quote\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"HyperNet","offers":[{"title":"Default Title","offer_id":51545072828649,"sku":"HN-MPO8-MPO8-OM4-400G","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/6262\/3465\/files\/03-mpo8-mpo8-om4-400g-product_a886c3fe-0add-4342-88dd-915aa6df71f6.png?v=1784527324"},{"product_id":"mpo-8-to-2x-mpo-8-om4-400g-to-2x200g-breakout-cable","title":"MPO-8 to 2x MPO-8 OM4 400G to 2x200G Breakout Cable","description":"\u003cdiv class=\"b2b-product-copy\"\u003e\n\u003cp\u003e\u003cstrong\u003eB2B RFQ product.\u003c\/strong\u003e This item is supplied to project requirements and is not sold at a fixed online price.\u003c\/p\u003e\n\u003cp\u003eAn OM4 multimode breakout cable that converts one 400G MPO optical interface into two 200G branches for short-reach AI and data-center links.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEight active fibers on the input side\u003c\/li\u003e\n\u003cli\u003eTwo branches with four active fibers per branch\u003c\/li\u003e\n\u003cli\u003eMPO\/APC female connector housings on all ends\u003c\/li\u003e\n\u003cli\u003eOM4 multimode construction with magenta cable\u003c\/li\u003e\n\u003cli\u003eCustom overall and branch lengths available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eFunction\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e400G to 2 x 200G optical breakout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eFiber type\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eOM4 multimode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eFiber mapping\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e8 active fibers to 2 x 4 active fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eInput connector\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e12-fiber MPO\/APC female housing, 8 active fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eOutput connectors\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e2 x 12-fiber MPO\/APC female housings, 4 active fibers per branch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eCable construction\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e3.0 mm input; 2 x 3.0 mm branches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eCable color\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eMagenta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eKey orientation\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eKey-up reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eFanout reference\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e0.2 m from input connector to fanout in the source drawing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e400G switch port to two 200G endpoints\u003c\/li\u003e\n\u003cli\u003eAI and HPC multimode fabrics\u003c\/li\u003e\n\u003cli\u003eShort-reach data-center breakout cabling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering note:\u003c\/strong\u003e The source slide defines construction and fiber mapping but not IL\/RL values; those values are intentionally not claimed.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003ePlease specify overall length, branch length, quantity, fiber mapping, jacket rating, labels, and destination country. OEM labeling, custom packaging, and project-specific test reports are available on request.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/fr\/pages\/contact\"\u003e\u003cstrong\u003eRequest a Quote\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"HyperNet","offers":[{"title":"Default Title","offer_id":51545072861417,"sku":"HN-MPO8-2MPO8-OM4-400G-2X200G","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/6262\/3465\/files\/04-mpo8-2x-mpo8-om4-400g-2x200g-product_da7193a0-0a39-4cd3-b561-c18cc8430256.png?v=1784527369"},{"product_id":"mpo-16-to-2x-mpo-8-om4-800g-to-2x400g-breakout-cable","title":"MPO-16 to 2x MPO-8 OM4 800G to 2x400G Breakout Cable","description":"\u003cdiv class=\"b2b-product-copy\"\u003e\n\u003cp\u003e\u003cstrong\u003eB2B RFQ product.\u003c\/strong\u003e This item is supplied to project requirements and is not sold at a fixed online price.\u003c\/p\u003e\n\u003cp\u003eAn OM4 breakout cable that divides one MPO-16 optical interface into two MPO-8 branches for 800G-to-dual-400G or 400G-to-dual-200G architectures.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSixteen active OM4 fibers\u003c\/li\u003e\n\u003cli\u003eMPO-16 APC female input and two MPO-8 APC female outputs\u003c\/li\u003e\n\u003cli\u003eLow-loss multimode construction\u003c\/li\u003e\n\u003cli\u003eReference branch length of 500 mm with custom options\u003c\/li\u003e\n\u003cli\u003eSuitable for 100G-PAM4 lane architectures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eFunction\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e800G to 2 x 400G, or 400G to 2 x 200G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eFiber type\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eOM4 multimode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eActive fiber count\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e16, split to 2 x 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eInput connector\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eMPO-16 APC female, aqua housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eOutput connectors\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e2 x MPO-8 APC female, aqua housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eCable\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e3.0 mm, magenta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eKey orientation\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eKey-up to key-up reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eInsertion loss\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e\u0026lt;= 0.35 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eReturn loss\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e\u0026gt;= 30 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eTest wavelengths\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e850 nm and 1300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eReference branch length\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e500 mm +50\/-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e800G AI-fabric breakout links\u003c\/li\u003e\n\u003cli\u003e400G to dual 200G interconnects\u003c\/li\u003e\n\u003cli\u003eHigh-density switch-to-adapter cabling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003ePlease specify overall length, branch length, quantity, lane mapping, jacket rating, labels, and destination country. OEM labeling, custom packaging, and project-specific test reports are available on request.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/fr\/pages\/contact\"\u003e\u003cstrong\u003eRequest a Quote\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"HyperNet","offers":[{"title":"Default Title","offer_id":51545072926953,"sku":"HN-MPO16-2MPO8-OM4-800G-2X400G","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/6262\/3465\/files\/06-mpo16-2x-mpo8-om4-800g-2x400g-product_afaa6e8e-5192-4d83-931a-e6770824a1e5.png?v=1784527420"},{"product_id":"mpo-16-to-mpo-16-om4-400g-ethernet-roce-patch-cable","title":"MPO-16 to MPO-16 OM4 400G Ethernet RoCE Patch Cable","description":"\u003cdiv class=\"b2b-product-copy\"\u003e\n\u003cp\u003e\u003cstrong\u003eB2B RFQ product.\u003c\/strong\u003e This item is supplied to project requirements and is not sold at a fixed online price.\u003c\/p\u003e\n\u003cp\u003eA 16-fiber OM4 MPO patch cable designed for low-latency 400G Ethernet RoCE links in AI training, storage, and high-performance data-center fabrics.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSixteen active OM4 multimode fibers\u003c\/li\u003e\n\u003cli\u003eMPO-16 APC female connectors at both ends\u003c\/li\u003e\n\u003cli\u003eKey-up to key-up reference orientation\u003c\/li\u003e\n\u003cli\u003eLow-loss performance for RoCE network paths\u003c\/li\u003e\n\u003cli\u003eCustom length, jacket, labeling, and packaging options\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eApplication\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e400G Ethernet RoCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eFiber type\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eOM4 multimode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eActive fiber count\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eConnector A\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eMPO-16 APC female, aqua housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eConnector B\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eMPO-16 APC female, aqua housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eCable\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e3.0 mm, magenta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eKey orientation\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eKey-up to key-up reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eInsertion loss\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e\u0026lt;= 0.35 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eReturn loss\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e\u0026gt;= 30 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eTest wavelengths\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e850 nm and 1300 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e400G Ethernet RoCE fabrics\u003c\/li\u003e\n\u003cli\u003eAI training and storage networks\u003c\/li\u003e\n\u003cli\u003eLow-latency data-center interconnects\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003ePlease specify required length, quantity, lane map, connector gender, jacket requirement, labels, and destination country. OEM labeling, custom packaging, and project-specific test reports are available on request.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/fr\/pages\/contact\"\u003e\u003cstrong\u003eRequest a Quote\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"HyperNet","offers":[{"title":"Default Title","offer_id":51545072992489,"sku":"HN-MPO16-MPO16-OM4-400G-ROCE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/6262\/3465\/files\/08-mpo16-mpo16-om4-400g-roce-product_2dde1788-3ce5-4874-9bde-a4530473403b.png?v=1784527468"},{"product_id":"mpo-16-apc-to-2x-mpo-8-pc-om4-400g-to-2x200g-roce-breakout-cable","title":"MPO-16 APC to 2x MPO-8 PC OM4 400G to 2x200G RoCE Breakout Cable","description":"\u003cdiv class=\"b2b-product-copy\"\u003e\n\u003cp\u003e\u003cstrong\u003eB2B RFQ product.\u003c\/strong\u003e This item is supplied to project requirements and is not sold at a fixed online price.\u003c\/p\u003e\n\u003cp\u003eA hybrid-polish OM4 breakout cable that converts one 400G MPO-16 interface into two 200G MPO branches for Ethernet RoCE applications.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMPO-16 APC female input connector\u003c\/li\u003e\n\u003cli\u003eTwo MPO-8 PC female output connectors\u003c\/li\u003e\n\u003cli\u003eOM4 multimode 16-fiber construction\u003c\/li\u003e\n\u003cli\u003eHybrid 8-degree APC to 0-degree PC interface design\u003c\/li\u003e\n\u003cli\u003eCustom overall and branch lengths available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eFunction\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e400G to 2 x 200G Ethernet RoCE breakout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eFiber type\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eOM4 multimode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eInput connector\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eMPO-16 APC female, aqua housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eOutput connectors\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e2 x MPO-8 PC female, aqua housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eInput polish\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eAPC, 8-degree\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eOutput polish\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003ePC, 0-degree\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eCable\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e3.0 mm, magenta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eReference branch length\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e500 mm +50\/-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eInsertion loss\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e\u0026lt;= 0.35 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eReturn loss\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e\u0026gt;= 20 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e400G to dual 200G Ethernet RoCE links\u003c\/li\u003e\n\u003cli\u003eAI training and storage fabrics\u003c\/li\u003e\n\u003cli\u003eHigh-density switch breakout cabling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering note:\u003c\/strong\u003e The source slide states APC input, PC outputs, IL \u0026lt;=0.35 dB, and RL \u0026gt;=20 dB; it does not state test wavelengths.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003ePlease specify overall length, branch length, quantity, lane map, polish configuration, labels, and destination country. OEM labeling, custom packaging, and project-specific test reports are available on request.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/fr\/pages\/contact\"\u003e\u003cstrong\u003eRequest a Quote\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"HyperNet","offers":[{"title":"Default Title","offer_id":51545073025257,"sku":"HN-MPO16-2MPO8-OM4-400G-2X200G-ROCE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/6262\/3465\/files\/09-mpo16-apc-2x-mpo8-pc-om4-400g-2x200g-roce-product_473ba30a-d83d-43f9-90ee-852489783667.png?v=1784527510"},{"product_id":"64-fiber-os2-4x-mmc-16-apc-to-8x-mpo-8-apc-shuffle-trunk-cable","title":"64-Fiber OS2 4x MMC-16 APC to 8x MPO-8 APC Shuffle Trunk Cable","description":"\u003cdiv class=\"b2b-product-copy\"\u003e\n\u003cp\u003e\u003cstrong\u003eB2B RFQ product.\u003c\/strong\u003e This item is supplied to project requirements and is not sold at a fixed online price.\u003c\/p\u003e\n\u003cp\u003eA 64-fiber OS2 shuffle trunk that converts four MMC-16 APC interfaces into eight MPO-8 APC interfaces with a factory-controlled polarity map.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSixty-four OS2 single-mode fibers\u003c\/li\u003e\n\u003cli\u003eFour MMC-16 APC female connectors on Side A\u003c\/li\u003e\n\u003cli\u003eEight MPO-8 APC female connectors on Side B\u003c\/li\u003e\n\u003cli\u003eColor-coded, serial-numbered, and staggered breakout legs\u003c\/li\u003e\n\u003cli\u003eCustom polarity map and production drawing approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eFiber type\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eOS2 single-mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eTotal fiber count\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eMain cable\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e8.0 mm OD with 4 x 16F subunits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eSide A\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e4 x MMC-16 APC female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eSide B\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e8 x MPO-8 APC female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eSide A furcation\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e2.5 mm maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eSide B furcation\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e3.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eInsertion loss\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003e\u0026lt;= 0.85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003ePolarity\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eCustom shuffle map with color-coded fiber-position identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:8px;border:1px solid #d9dee7;\"\u003eBreakout construction\u003c\/th\u003e\n\u003ctd style=\"padding:8px;border:1px solid #d9dee7;\"\u003eStaggered legs; End 2 breakout tolerance +80\/-0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNext-generation high-density fiber distribution\u003c\/li\u003e\n\u003cli\u003eAI and HPC data-center shuffle trunks\u003c\/li\u003e\n\u003cli\u003eMMC-to-MPO migration and conversion systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering note:\u003c\/strong\u003e Source page 25 provides the full 64-position shuffle map and a maximum insertion loss of 0.85 dB.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003ePlease specify overall length, breakout sequence, polarity map, quantity, jacket rating, labels, test-report format, and destination country. OEM labeling, custom packaging, and project-specific test reports are available on request.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/fr\/pages\/contact\"\u003e\u003cstrong\u003eRequest a Quote\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"HyperNet","offers":[{"title":"Default Title","offer_id":51545073123561,"sku":"HN-SHUFFLE-64F-4MMC16-8MPO8-SM","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0818\/6262\/3465\/files\/12-64f-4x-mmc16-apc-8x-mpo8-apc-sm-shuffle-trunk-product_36551222-8a05-46b5-a0d6-99cc877ea3e6.png?v=1784527620"}],"url":"https:\/\/hpnetdc.com\/fr\/collections\/fiber-patch-cables.oembed","provider":"HyperNet Technology","version":"1.0","type":"link"}